EVO Series™
An evolution in fluid technology. This revolutionary pump takes the best of many positive displacement pump technologies and combines them into a single product. The result: All the performance you want in a breakthrough pump technology. There is no other pump on the market that has all the hallmarks of an air-driven diaphragm pump, plus superior efficiency, minimal pulsation and the ability to be fully integrated into process control. A highly efficient and self-priming pump without dynamic seals, which also conveys viscous or abrasive media in a gentle manner and at the same time has no problems with dry running or working against a closed slide. The unique design ensures comprehensive protection for your employees, trouble-free processes and low operating costs.

Evolution No Smoke
Self-supporting suction arm for extraction of welding fumes, gases, vapors, aerosols, oil fumes and dusts, designed and constructed in compliance with the regulations on the timely elimination of pollutants in working environments. HIghlights: - New Winghood hood designed to improve smoke capture by 30 % - Patented external joint that does not obstruct the passage of air and pollutants and allows convenience in arm adjustment and movement (up to 360°) - Built-in regulation damper to dose the necessary amount of air to be sucked in and save energy - Heavy-duty sheet metal piping (galvanized, stainless, scratch-resistant painted, aluminum) - Green solution: ideal for energy saving and quiet operation, especially when combined with inverter on the fan - No air passage obstruction due to patented external joint system, with lower pressure drop - Can be mounted with flag extensions, vacuum ducts, wall or ceiling brackets

Ex and Functional Safety
Ex & Functional Safety: We don’t make safety compromises In challenging environments such as bulk material handling, safety is crucial. We have certified expertise in explosion protection and functional safety: ATEX/IECEx Compliance: Our engineers are IECEx certified (Units Ex 001, Ex 003, Ex 009), ensuring that every designed system meets the rigorous IEC 60079 standards for explosive atmospheres. Functional Safety: As Certified Experts in Functional Safety (CEFS), we design control systems that meet the highest SIL (Safety Integrity Level) and PL (Performance Level) requirements in accordance with ISO 13849 and IEC 62061. From risk assessment to final implementation, we ensure your plant and personnel are protected.

Ex Barriers
The Series N-132... isolating switching amplifiers (Ex Barrier) transmit switching operations from an intrinsically safe control circuit to a non-intrinsically safe active current circuit. The control units are designed according to NAMUR-DIN 19234 or EN 60947-5-6 intrinsically safe and according to IEC 60079 [Ex ia] II C. The conformity is certified in Germany by DEKRA EXAM GmbH.

EX8000™ Multi Zone Control Unit
The EX8000™ Multi Zone Control Unit is responsible for the protection system control and status verification functions. The electronic system is integrated on a modern and reliable board with redundant circuitry for all safety functions. Power supply, emergency battery and connection technology are all accommodated within the cabinet. All signals from the explosion pressure, spark, flame or temperature sensors employed in the protection system are recorded, tested and evaluated by the EX8000. The monitoring and activation circuits are continuously checked with regard to wire breakage, earth fault and short circuit. In addition, an automatic self-test system ensures that all safety relevant functions of the EX8000 are monitored. In case of power failure the emergency battery automatically takes over without interruption and can be sustained from 4 hours to 24 hours, depending on the application requirement. All fault and alarm messages are displayed by both light emitting diodes (LED) and the EX8000 front panel display which can also be forwarded by means of potential-free contacts. The EX8000 offers maximum flexibility to users of multi actuation zone applications through its modular approach. Depending on the configuration of the explosion protection system the related protection measures are activated selectively. The EX8000 base unit allows control and indication of four detection and activation circuits (zones). This can be scaled-up depending on the needs of the application, up to 16 zones within one standard wall mount unit. The floor mounted cabinet version can handle even up to 32 zones. These features make the EX8000 the most comprehensive solution on the market.

Excavator Scale
The PFREUNDT excavator scale enables to weigh directly during the work process and thus fast and accurate loading of transport vehicles. The excavator scale ensures transparancy in the material flow and can be retrofittet at any time in excavators of all manufacturer types with mono booms.

ExCharge® filter for optimum explosion protection
ExCharge® is an anti-static needle felt. High quality stainless steel fibres in the supporting scrim provide the necessary discharge. At a glance - Optimal discharge of electrostatic charge - Permanent antistatic behaviour by means of sophisticated steel fibres
EXKOP quench valve
Firstly, the tried and trusted EXKOP QV II is now also available for dust class 2 and a reduced explosion pressure (pred) of up to 2 bar. In addition, the launch of the EXKOP QV III, the new big brother of the QV II, means it is now possible to protect lines with diameters of between 300 and 600 mm. With an innovative, space-saving design, it can even be installed in confined areas where space is at a premium. Direct integration of the pressure storage tank keeps the dimensions to the minimum.

Explosion Protection: Venting

Explosion suppresion system
The ANTIDET Suppressor protective system serves to suppress a dust explosion within a protected facility by actively interfering with the process of burning (extinguishing). An explosion suppression system must often be combined with an explosion separation system.

EXPLOSION SUPPRESSION
Fike suppression systems are designed to detect and chemically suppress an explosion in its earliest stages – before an explosion can cause a disaster or become catastrophic. While un-suppressed explosion pressures reach dangerous levels in less than 50 milliseconds, Fike’s unique technology can detect and respond in less than 1 millisecond – averting a catastrophe.

Explosion Vent panels
VIGILEX explosion vent panels meet all the essential health and safety requirements for even an explosive atmosphere (Directive 94/9/CE) . In case of a fire, the explosion vents are designed to evacuate : the pressure, flames and dusts, thereby protecting people and the industrial equipment. A simple and efficient protection system : VIGILEX explosion vents are made to resist depressions, pneumatic unclogging cycles, and to be used on silos, hoppers, filters and cyclones. Conformity : CE Certification and Production Quality Assurance Notification.

Explosion venting
The ANTIDET Relief protective system serves to relieve the explosion pressure and other products of an explosion into the environment of the protected facility. It is a passive element and does not in any way involve itself in the burning process during an explosion. As all explosion venting systems require a delineation of a sufficient safety zone for venting explosion products, which forbid the presence of individuals, barriers, or environment at risk of an explosion. It further requires the integration with the explosion venting system.

Explosions-Berstscheibe

Explosive Cleaning
For severe encrustations or large blockages in silos and vessels, controlled explosive cleaning is used. Targeted charges break up hardened material deposits and restore product flow without causing damage to the installation. This highly specialised method is carried out exclusively by certified personnel authorised for explosive operations.
2542 results found